VTSA-F-FB-AP
Data sheet
Overall data sheet-Individual values depend upon your configuration.
|
Feature |
value |
|
Electrical control |
AP interface Fieldbus |
|
Electrical l/O system |
yes |
|
Terminal type |
45 |
|
Protocol |
AP |
|
Type of mounting |
Direct mounting via through-hole On H-rail via accessories On mounting frame Screw-clamped With through-hole for M5 screw with accessories With through-hole for M6screw with accessories Via through-hole for M5 screw Via through-hole for M6 screw |
|
Max.number of modules |
15 |
|
Mounting position |
Any,on H-rail:horizontal |
|
Operating medium |
Compressed air to ISO 8573-1:2010[7:4:4] |
|
Note on operating and pilot medium |
Lubricated operation possible(in which case lubricated operation will always be required) |
|
Ambient temperature |
-5℃...50℃ |
|
Note on ambient temperature |
observe ambient temperature derating according to IEC61131-2:2017 |
|
Storage temperature |
-20C...60℃ |
|
Relative air humidity |
5-90% Non-condensing |
|
Nominal altitude of use |
(=2000m ASL(>79.5kPa) |
|
Max.installation height |
3500 m |
|
Note on max.installation height |
>2000 m ASL(79.5 kPa) Observe ambient temperature derating according to IEC 61131-2:2017 |
|
Degree of protection |
IP65 |
|
Note on degree of protection |
Unused connections sealed |
|
Corrosion resistance class CRC |
0-No corrosion stress |
|
Protection against direct and indirect contact |
SELV/PELV power supply units required |
|
Pollution degree |
2 |
|
Operating pressure |
-0.09 MPa...1 MPa |
|
Operating pressure |
-0.9 bar...10 bar |
|
Pilot pressure |
0.3 MPa...1 MPa |
|
Pilot pressure |
3 bar...10 bar |
|
Operating pressure for valve terminal with internal pilot air supply |
0.3 MPa...1 MPa |
|
Operating pressure for valve terminal with internal pilot air supply |
3 bar...10 bar |
|
Feature |
Value |
|
Operating pressure for valve terminal with internal pilot air supply |
43.5 psi...145 psi |
|
LABS(PWIS)conformity |
VDMA24364-B1/B2-L |
|
CE mark(see declaration of conformity) |
To EU EMC Directive In accordance with EU RoHS Directive |
|
CE marking (see declaration of conformity) |
To UKinstructions for EMC To UK RoHSinstructions |
|
KC mark |
KC-EMV |
|
Approval |
RCM trademark |
|
Note on materials |
RoHS-compliant Free of halogen Free of phosphoric acid ester |
|
Valve terminal structure |
Modular,valve sizes can be mixed |
|
Max.number of valve positions |
32 |
|
Max.number of pressure zones |
16 |
|
Type of actuation |
Electric |
|
Valve function |
2x2/2-way,monostable,closed 2×3/2-way,monostable,closed 2×3/2-way,open,monostable 2×3/2-way,open/closed,monostable 5/2 double solenoid 5/2-way,bistable,dominant 5/2-way,monostable 5/2-way,monostable,safety function 5/3-way,pressurised 5/3exhausted 5/3 closed 5/3-way,port 2 pressurised,4 exhausted |
|
Design |
Piston gate valve |
|
Valve size |
65 mm |
|
Pilot air supply |
External Internal |
|
Max.standard nominal flow rate |
7001/min at 18mm 13501/min at 26mm 1860 I/min at 42 mm 2900 I/min at 52 mm 40001/min at 65 mm |
|
Suitability for vacuum |
yes |
|
Exhaust-air function |
Via throttle plate |
|
pneumatic working port |
G1/8 G1/4 G3/8 G1/2 1/8 NPT 1/4 NPT 3/8 NPT 1/2NPT QS-6 QS-8 QS-10 QS-12 QS-14 QS-16 QS-5/16 QS-3/8 QS-1/2 |
|
Signal status display |
LED |
|
Note on fieldbus interface |
All information that is relevant to CPX-AP can be read out via the Ethernet interfaces/fieldbus connections and changed depending on the function. Auto MDI,the bus module performs a crossover check Firmware update via Ethernet interface/fieldbus interface &M function according to PNO is supported. Based on the Ethernet protocol IEEE 802.3 |
|
Fieldbus interface |
Ethernet |
|
Feature |
value |
|
Field bus,protocol |
ACD (Address Conflict Detection) DLR(Device Level Ring) EtherCAT® EtherCAT CoE EtherCAT Distributed Clocks(DC) EtherCAT EoE EtherCAT FoE EtherCAT Modular Device Profile(MDP) EtherNet/IP EtherNet/IP QoS EtherNet/IP Quickconnect LLDP MRP,MRPD(ring redundancy) Modbus/TCP(Modbus/UDP) PROFINET FSU PROFINET I&M0..3 PROFINET IRT PROFINET RT PROFINET shared device S2 system redundancy SNMP |
|
Fieldbus interface,function |
Bus connection incoming/outgoing |
|
Field bus,connection type |
2x socket |
|
Field bus,connection system |
M12x1,D-coded to EN 61076-2-101 RJ45 to IEC 61076-3-117(V14) SCRJ to IEC 61754-24-21 |
|
Field bus,connection pattern |
2...8 |
|
Field bus interface,electrical isolation |
yes |
|
Field bus interface,transmission rate |
100 Mbit/s |
|
Max.address volume,inputs |
4096 Byte |
|
Note on inputs |
EP:488 bytes Modbus:4096 bytes |
|
Max.address volume,outputs |
4096 Byte |
|
Note on outputs |
EP:496 bytes Modbus:4096 bytes |
|
Internal cycle time |
<1ms |
|
Configuration support |
EDS file ESl file GSDML file IODD file |
|
Power supply,function |
Incoming electronics/sensors and load and functional earth |
|
Power supply,connection type |
Plugs |
|
power supply,connection system |
7/8“to NFPA/T3.5.29 M12x1,L-coded to EN 61076-2-111 M18x1 Push-pull to IEC61076-3-126 |
|
Power supply,number of pins/wires |
4….5 |
|
Note regarding operating voltage |
SELV/PEIV fixed power supplies required Note voltage drop |
|
Nominal operating voltage DC |
24V |
|
Note on nominal operating voltage DC |
Protected Extra-Low-Voltage to IEC60204-1 |
|
Permissible voltage fluctuations |
+/-10% |
|
Nominal DC operating voltage,electronics/sensors |
24V |
|
Permissible voltage fluctuations for electronics/sensors |
±25% |
|
Max.power supply |
8A...16A |
|
Typ.intrinsic current consumption at nominal operating voltage for electronic system/sensors |
40 mA....10000 mA |
|
Typ.intrinsic current consumption at nominal operating voltage,load |
3 mA...10000 mA |
|
Power failure bridging |
10ms |
|
Potential separation between the supply voltages electronics/sensor technology and load/valves |
Yes |
|
Reverse polarity protection |
yes |